Refine your search:     
Report No.
 - 
Search Results: Records 1-13 displayed on this page of 13
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Heterogeneity effects in micro-beam XRF scanning spectroscopy of binary powdered mixtures and lake sediments

Katsuta, Nagayoshi*; Umemura, Ayako*; Naito, Sayuri*; Masuki, Yuma*; Itayama, Yui*; Niwa, Masakazu; Shirono, Shinichi*; Yoshida, Hidekazu*; Kawakami, Shinichi*

Spectrochimica Acta, Part B, 210, p.106817_1 - 106817_11, 2023/12

 Times Cited Count:0 Percentile:0.02(Spectroscopy)

X-ray fluorescence (XRF) scanning of lacustrine sediments has been used to extend the approach to a wider range of elemental records in both ages and timescales of variations in past environments and climates. However, one of severe problems with effects of the XRF intensity by grain size and mineralogical composition known as "heterogeneity effects" have been pointed out. This study investigated the heterogeneity effect of Fe intensities on X-ray beam using several binary powder mixtures and lacustrine sediment cores.

Journal Articles

Spectrum prediction in X-ray fluorescence analysis using Bayesian estimation

Matsuyama, Tsugufumi*; Nakae, Masanori*; Murakami, Masashi; Yoshida, Yukihiko; Machida, Masahiko; Tsuji, Koichi*

Spectrochimica Acta, Part B, 199, p.106593_1 - 106593_6, 2023/01

 Times Cited Count:2 Percentile:45.92(Spectroscopy)

Journal Articles

Spectrochemistry of technetium by liquid electrode plasma optical emission spectrometry and its applicability of quantification for highly active liquid waste

Yamamoto, Masahiko; Do, V. K.; Taguchi, Shigeo; Kuno, Takehiko; Takamura, Yuzuru*

Spectrochimica Acta, Part B, 155, p.134 - 140, 2019/05

 Times Cited Count:5 Percentile:41.96(Spectroscopy)

The emission spectra of technetium (Tc) by liquid electrode plasma optical emission spectrometry have been investigated in this study. From the spectra, 52 emission peaks of Tc were observed in the 250-500 nm wavelength range. All peaks were assigned to the neutral state or singly ionized state. The relative intensities of these peaks were similar to those excited by an electric spark. The strongest intensity peaks were found at 254.3 nm, 261.0 nm, and 264.7 nm. Spectral interferences of coexisting elements in highly active liquid waste of reprocessing stream on those three strongest peaks were investigated using simulated sample. No spectral interferences were observed around the 264.7 nm Tc peak. Therefore, analytical performance using 264.7 nm peak was evaluated. The detection limit, estimated on standard and blank samples in 0.4 M nitric acid, was 1.9 mg/L. The relative standard deviation of Tc standard sample (12.0 mg/L) was 3.8% (N = 5, 1$$sigma$$).

Journal Articles

Laser ablation absorption spectroscopy for isotopic analysis of plutonium; Spectroscopic properties and analytical performance

Miyabe, Masabumi; Oba, Masaki; Jung, K.; Iimura, Hideki; Akaoka, Katsuaki; Kato, Masaaki; Otobe, Haruyoshi; Khumaeni, A.*; Wakaida, Ikuo

Spectrochimica Acta, Part B, 134, p.42 - 51, 2017/08

 Times Cited Count:30 Percentile:91.46(Spectroscopy)

Spectroscopic properties of atomic species of plutonium were investigated by combining laser ablation and resonance absorption techniques for the analysis of a plutonium oxide sample. For 17 transitions of Pu atoms and ions, the absorbance, isotope shift, and hyperfine splitting were determined via Voigt profile fitting of the recorded absorption spectra. Three transitions were selected as candidates for analytical use. Using these transitions, we investigated the analytical performance that was attainable and determined a correlation coefficient R2 between the absorbance and plutonium concentration of 0.9999, a limit of detection of 30-130 ppm, and a relative standard deviation of approximately 6% for an abundance of $$^{240}$$Pu of 2.4%. These results demonstrate that laser ablation absorption spectroscopy is applicable to the remote isotopic analysis of highly radioactive nuclear fuels and waste materials containing multiple actinide elements.

Journal Articles

Ablation plume structure and dynamics in ambient gas observed by laser-induced fluorescence imaging spectroscopy

Miyabe, Masabumi; Oba, Masaki; Iimura, Hideki; Akaoka, Katsuaki; Khumaeni, A.*; Kato, Masaaki; Wakaida, Ikuo

Spectrochimica Acta, Part B, 110, p.101 - 117, 2015/08

AA2015-0183.pdf:3.11MB

 Times Cited Count:25 Percentile:82.1(Spectroscopy)

The dynamic behavior of an ablation plume in ambient gas has been investigated by laser-induced fluorescence imaging spectroscopy. The second harmonic beam from an Nd:YAG laser (0.5-6J/cm$$^{2}$$) was focused on a sintered oxide pellet or a metal chip of gadolinium. The produced plume was subsequently intersected with a sheet-shaped UV beam from a dye laser so that time-resolved fluorescence images were acquired with an intensified CCD camera at various delay times. The obtained cross-sectional images of the plume indicate that the ablated ground state atoms and ions of gadolinium accumulate in a hemispherical contact layer between the plume and the ambient gas, and a cavity containing a smaller density of ablated species is formed near the center of the plume. At earlier expansion stage, another luminous component also expands in the cavity so that it coalesces into the hemispherical layer. The splitting and coalescence for atomic plume occur later than those for ionic plume. Furthermore, the hemispherical layer of neutral atoms appears later than that of ions; however, the locations of the layers are nearly identical. This coincidence of the appearance locations of the layers strongly suggests that the neutral atoms in the hemispherical layer are produced as a consequence of three-body recombination of ions through collisions with gas atoms. The obtained knowledge regarding plume expansion dynamics and detailed plume structure is useful for optimizing the experimental conditions for ablation-based spectroscopic analysis.

Journal Articles

Design of an apparatus for polarization measurement in soft X-ray region

Imazono, Takashi; Suzuki, Yoji; Sano, Kazuo*; Koike, Masato

Spectrochimica Acta, Part B, 65(2), p.147 - 151, 2010/02

 Times Cited Count:2 Percentile:14.6(Spectroscopy)

To meet the needs we have been developing an apparatus to evaluate polarization abilities of multilayer- and crystal-types polarizing elements and determine the polarization state of light in 1 keV region. The 8-axis goniometer called the polarization analysis-unit is equipped in this apparatus and consists of a phase shifter-unit and an analyzer-unit. All axes can be driven with HV compatible stepping motors. Both reflection- and transmission-types samples are available on P and A. Therefore, this apparatus makes it possible to carry out not only conventional reflection and transmission measurements but also four scanning modes which are double- reflections and transmissions, and transmission-reflection and vice versa.

Journal Articles

Development of soft X-ray multilayer laminar-type plane gratings and varied-line-spacing spherical grating for flat-field spectrograph in the 1-8 keV region

Koike, Masato; Ishino, Masahiko; Imazono, Takashi; Sano, Kazuo*; Sasai, Hiroyuki*; Hatayama, Masatoshi*; Takenaka, Hisataka*; Heimann, P. A.*; Gullikson, E. M.*

Spectrochimica Acta, Part B, 64(8), p.756 - 760, 2009/08

 Times Cited Count:9 Percentile:42.95(Spectroscopy)

W/C and Co/SiO$$_{2}$$ multilayer laminar-type holographic plane gratings (groove density 1/1200 lines /mm) in the 1-8 keV region are developed. For the Co/SiO$$_{2}$$ grating the diffraction efficiencies of 0.41 and 0.47 at 4 and 6 keV, respectively, and for the W/C grating 0.38 at 8 keV are observed. Taking advantage of the outstanding high diffraction efficiencies into practical soft X-ray spectrographs a Mo/SiO$$_{2}$$ multilayer varied-line-spacing (VLS) laminar-type spherical grating (1/2400 lines /mm) is also developed for use with a flat field spectrograph in the region of 1.7 keV. For the Mo/SiO$$_{2}$$ multilayer grating the diffraction efficiencies of 0.05-0.20 at 0.9-1.8 keV are observed. The FWHM's of the measured line profiles of Hf-M$$alpha$$$$_{1}$$ (1644.6 eV), Si-K$$alpha$$$$_{1}$$ (1740.0 eV),and W-M$$alpha$$$$_{1}$$ (1775.4 eV) are 13.7 eV, 8.0 eV, and 8.7 eV, respectively. It shows the validity of multilayer lamina-type gratings in the region.

Journal Articles

Isotopic analysis of single uranium and plutonium particles by chemical treatment and mass spectrometry

Shinonaga, Taeko*; Esaka, Fumitaka; Magara, Masaaki; Klose, D.*; Donohue, D.*

Spectrochimica Acta, Part B, 63(11), p.1324 - 1328, 2008/11

 Times Cited Count:38 Percentile:84.81(Spectroscopy)

The isotopic composition of single uranium and plutonium particles was measured with an inductively coupled plasma mass spectrometer (ICP-MS) and a thermal ionization mass spectrometer (TIMS). The particles prepared on a carbon planchet were first analyzed with an energy dispersive X-ray spectrometer (EDX) attached to a scanning electron microscope (SEM) and then transferred on to a silicon wafer using a manipulator. The particle on the silicon wafer was dissolved with nitric acid and the isotopic ratios of U and Pu were measured with ICP-MS and TIMS. The results obtained by both methods showed good agreement with the certified values within the expected uncertainty. The measurement uncertainties obtained in this study were similar for both mass spectrometric methods. This study was performed to establish the method of particle analysis with SEM, EDX, the particle manipulation technique, and the measurement of isotope ratios of U and Pu in a single particle by mass spectrometry.

Journal Articles

Application of Inductively coupled plasma Mass Spectrometry to the determination of uranium isotope ratios in individual particles for nuclear safeguards

Zhang, X. Z.*; Esaka, Fumitaka; Esaka, Konomi; Magara, Masaaki; Sakurai, Satoshi; Usuda, Shigekazu; Watanabe, Kazuo

Spectrochimica Acta, Part B, 62(10), p.1130 - 1134, 2007/10

 Times Cited Count:23 Percentile:70.33(Spectroscopy)

The capability of inductively coupled plasma mass spectrometry (ICP-MS) for the determination of uranium isotope ratios in individual particles was determined. For this purpose, we developed an experimental procedure including single particle transfer with a manipulator, chemical dissolution and isotope ratio analysis. As the result, the $$^{235}$$U/$$^{238}$$U isotope ratio for the particle with the diameter between 0.5 and 3.9 $$mu$$m was successfully determined with the deviation from the certified ratio within 1.8%. The developed procedure was successfully applied to the analysis of a simulated environmental sample prepared from a mixture of indoor dust (NIST SRM 2583) and uranium particles (NBL CRM U050, U350 and U950a). From the results, the proposed procedure was found to be an alternative analytical tool for nuclear safeguards.

Journal Articles

Evaluation of carbon films on the Japanese smoked roof tile "Ibushi-Kawara" by angle-dependent soft X-ray emission spectroscopy using synchrotron radiation

Muramatsu, Yasuji; Yamashita, Michiru*; Motoyama, Muneyuki*; Denlinger, J. D.*; Gullikson, E. M.*; Perera, R. C. C.*

Spectrochimica Acta, Part B, 59(8), p.1317 - 1322, 2004/08

 Times Cited Count:2 Percentile:10.2(Spectroscopy)

Polarized emission spectra from graphite have been measured by an EPMA and discussed by means of molecular orbital calculation of 2p electrons densities of state of graphite by some of the present authors. The present study treats the refined measurements of the polarized C K-emission band spectra from the highly oriented pyrolytic graphite (HOPG) and discusses the structure of the surface carbons of Japanese traditional smoked roof tiles, Ibushi Kawara.

Journal Articles

The Use of Si carriers for aerosol particle collection and subsequent elemental analysis by total-reflection X-ray fluorescence spectrometry

Esaka, Fumitaka; Watanabe, Kazuo; Onodera, Takashi; Taguchi, Takuji; Magara, Masaaki; Usuda, Shigekazu

Spectrochimica Acta, Part B, 58(12), p.2145 - 2155, 2003/12

 Times Cited Count:20 Percentile:62.39(Spectroscopy)

In order to improve the sensitivity of elemental analysis for aerosol particles by total-reflection X-ray fluorescence spectrometry (TXRF), silicon wafer carriers with diameters of 25 mm were selected and prepared for direct impact collection and subsequent analysis. The detection limits of elements on the carrier were determined and found to be superior to those on glassy carbon and quartz glass carriers used in previous studies. By using the silicon wafer carriers, aerosol particles with the sizes of $$>$$2.0 $$mu$$m, 0.3-2.0 $$mu$$m and 0.05-0.3 $$mu$$m were collected at Ibaraki in Japan from January to August 2002 and analyzed by TXRF. Selenium Consequently, the elements with the concentration of ng/m$$^{3}$$ &8211; pg/m$$^{3}$$ in the particles were successfully detected. The results revealed that K, V, Zn, Br and Pb were concentrated in fine particles, which is presumed to arise from anthropogenic sources. In contrast, Ca, Ti and Fe were contained in coarse particles, which is presumed to arise from soil.

Journal Articles

Observation of spectral line profiles emitted by an inductively coupled plasma, I; On the wavelength shift of spectral lines

; ;

Spectrochimica Acta, Part B, 39(8), p.979 - 991, 1984/00

 Times Cited Count:9 Percentile:70.84(Spectroscopy)

no abstracts in English

Journal Articles

Construction and performance of a newly developed X-ray excited optical luminescence spectrometer

; ; *; *

Spectrochimica Acta, Part B, 36(7), p.687 - 695, 1981/00

 Times Cited Count:5 Percentile:51.78(Spectroscopy)

no abstracts in English

13 (Records 1-13 displayed on this page)
  • 1